Main index | Section 7 | Options |
if the time stamp is applied to the packet when the networking stack receives the packet, the networking stack might not see the packet until an interrupt is delivered for the packet or a timer event causes the networking device driver to poll for packets, and the time stamp might not be applied until the packet has had some processing done by other code in the networking stack, so there might be a significant delay between the time when the last bit of the packet is received by the capture device and when the networking stack time-stamps the packet; | |
the timer used to generate the time stamps might have low resolution, for example, it might be a timer updated once per host operating system timer tick, with the host operating system timer ticking once every few milliseconds; | |
a high-resolution timer might use a counter that runs at a rate dependent on the processor clock speed, and that clock speed might be adjusted upwards or downwards over time and the timer might not be able to compensate for all those adjustments; | |
the host operating system's clock might be adjusted over time to match a time standard to which the host is being synchronized, which might be done by temporarily slowing down or speeding up the clock or by making a single adjustment; | |
different CPU cores on a multi-core or multi-processor system might be running at different speeds, or might not have time counters all synchronized, so packets time-stamped by different cores might not have consistent time stamps. | |
Some capture devices on some platforms can provide time stamps for packets; those time stamps are usually high-resolution time stamps, and are usually applied to the packet when the first or last bit of the packet arrives, and are thus more accurate than time stamps provided by the host operating system. Those time stamps might not, however, be synchronized with the host operating system's clock, so that, for example, the time stamp of a packet might not correspond to the time stamp of an event on the host triggered by the arrival of that packet.
Depending on the capture device and the software on the host, libpcap might allow different types of time stamp to be used. The pcap_list_tstamp_types(3) routine provides, for a packet capture handle created by pcap_create(3) but not yet activated by pcap_activate(3), a list of time stamp types supported by the capture device for that handle. The list might be empty, in which case no choice of time stamp type is offered for that capture device. If the list is not empty, the pcap_set_tstamp_type(3) routine can be used after a pcap_create() call and before a pcap_activate() call to specify the type of time stamp to be used on the device. The time stamp types are listed here; the first value is the #define to use in code, the second value is the value returned by pcap_tstamp_type_val_to_name(3) and accepted by pcap_tstamp_type_name_to_val(3) .
PCAP_TSTAMP_HOST - host Time stamp provided by the host on which the capture is being done. The precision of this time stamp is unspecified; it might or might not be synchronized with the host operating system's clock. PCAP_TSTAMP_HOST_LOWPREC - host_lowprec Time stamp provided by the host on which the capture is being done. This is a low-precision time stamp, synchronized with the host operating system's clock. PCAP_TSTAMP_HOST_HIPREC - host_hiprec Time stamp provided by the host on which the capture is being done. This is a high-precision time stamp; it might or might not be synchronized with the host operating system's clock. It might be more expensive to fetch than PCAP_TSTAMP_HOST_LOWPREC. PCAP_TSTAMP_ADAPTER - adapter Time stamp provided by the network adapter on which the capture is being done. This is a high-precision time stamp, synchronized with the host operating system's clock. PCAP_TSTAMP_ADAPTER_UNSYNCED - adapter_unsynced Time stamp provided by the network adapter on which the capture is being done. This is a high-precision time stamp; it is not synchronized with the host operating system's clock.
By default, when performing a live capture or reading from a savefile, time stamps are supplied as seconds since January 1, 1970, 00:00:00 UTC, and microseconds since that seconds value, even if higher-resolution time stamps are available from the capture device or in the savefile. If, when reading a savefile, the time stamps in the file have a higher resolution than one microsecond, the additional digits of resolution are discarded.
The pcap_set_tstamp_precision(3) routine can be used after a pcap_create() call and after a pcap_activate() call to specify the resolution of the time stamps to get for the device. If the hardware or software cannot supply a higher-resolution time stamp, the pcap_set_tstamp_precision() call will fail, and the time stamps supplied after the pcap_activate() call will have microsecond resolution.
When opening a savefile, the pcap_open_offline_with_tstamp_precision(3) and pcap_fopen_offline_with_tstamp_precision(3) routines can be used to specify the resolution of time stamps to be read from the file; if the time stamps in the file have a lower resolution, the fraction-of-a-second portion of the time stamps will be scaled to the specified resolution.
The pcap_get_tstamp_precision(3) routine returns the resolution of time stamps that will be supplied; when capturing packets, this does not reflect the actual precision of the time stamp supplied by the hardware or operating system and, when reading a savefile, this does not indicate the actual precision of time stamps in the file.
8 March 2015 | PCAP-TSTAMP (7) |
Main index | Section 7 | Options |
Please direct any comments about this manual page service to Ben Bullock. Privacy policy.